Chongqing Gold M&E Equipment Co.,Ltd
|
Gold Index: 8195
Payment Terms: | T/T,L/C,WU |
Place of Origin: | Chongqing, China (Mainland) |
![]() |
|
Add to My Favorites | |
HiSupplier Escrow |
This Current Transformer CT Testing Equipment uses high-performance DSP and ARM, advanced manufacturing process to ensure that the product is stable and reliable, full-featured, high degree of automation, high test efficiency, is the professional testing equipment for the Current transformer and Power Transformer CT / PT industry.
Test Standard
GDVA404 Current Transformer CT Testing Equipments Conforms: IEC60044-1, IEC60044-6, GB1208, GB16847, C57.13
Application:
Tests for current transformer: | |
1 | Excitation curve and parameters test |
2 | Turns ratio test |
3 | Ratio and phase error test |
4 | Polarity mark check |
5 | Coil resistance measurement |
6 | Secondary loop burden measurement |
7 | Error line curve test for protection CT |
8 | Transient CT parameters test |
9 | CT nameplate guess |
10 | Saturation hysteresis loop curve measurement |
Tests for voltage transformer: | |
1 | Turns ratio test and phase angle error test |
2 | Polarity test |
3 | Secondary burden test |
4 | Coil resistance test |
Applications for CTPT analyzer: | |
1 | CT nameplate check |
2 | CT parameters check in work burden |
3 | CT transient parameters analysis |
4 | CT ratio and phase error calibration |
5 | PT routine test |
CTPT Analyzer Technical Index:
1 | Test standards | IEC60044-1, IEC60044-6, GB1208, GB16847, C57.13 |
2 | Power supply | AC220V±10%,50Hz/60Hz±10% |
3 | Power output | 0.1~180V (AC) |
4 | Current output | 0.001~5A(RMS) |
5 | Power output | 300VA |
6 | Maximum knee voltage measurement | 45kv |
7 | Current measurement | Range:0~10A (automatically change range in 0.1/0.4/2/10A) |
Error <±0.1%+0.01%FS | ||
8 | Voltage measurement | Range:0~200 V (automatically change range in 1V/10V/70V/200V) |
Error < ±0.1%+0.01%FS | ||
9 | Turns ratio measurement | Range :1~35000, |
1~2000 error<0.05% | ||
2000~5000 error>0.1% | ||
5000~35000 error<0.2% | ||
10 | Phase measurement | error:±2min,resolution:0.01min |
11 | Coil resistance measurement | Range:0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm) |
Error< 0.2%RDG+0.02%FS | ||
Maximum resolution:0.1mΩ | ||
12 | Temperature measurement | -50~100 Celsius degree, error<3 Celsius degree |
13 | CT Secondary burden | Range 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm) |
Error <0.2%RDG+0.02%FS | ||
Maximum resolution 0.001ohm | ||
14 | PT Secondary burden | Range 0~80kohm (automatically change range in 800ohm/8kohm/80kohm) |
Error <0.2%RDG+0.02%FS | ||
Maximum resolution: 0.1ohm | ||
15 | PT ratio measurement | Range :1~35000, |
1~5000 error<0.2% | ||
5000~35000 error<0.5% | ||
16 | Saved data groups | >1000groups |
17 | Work condition | Temperature:-10°C~50°C, moist:≤90% |
18 | Size | 485mm×356mm×183mm |
19 | Weight | <15Kg |
Name | quantity | Description |
Host | 1 | |
3M mask cable | 2 | |
10M mask cable | 1 | |
Grounding cable 6M | 1 | Diameter size large than4MM |
Big test pliers | 2 | One red and one black |
Test gasket | 4 | Two red and two black |
Test pin | 4 | Two red and two black |
Test pliers | 4 | Two red and two black |
Power cable | 1 | |
Accessories bag | 1 | |
Production disk | 1 | Include Analysis application and instruction manual |
Instruction manual | 1 | |
Inspection report | 1 | |
Pass certificate | 1 |
Chongqing Gold M&E Equipment Co.,Ltd [China (Mainland)]
Business Type:Manufacturer, Trading Company
City: Chongqing
Province/State: Chongqing
Country/Region: China (Mainland)